Item |
specifications
|
Rated
Voltage Range(V) |
200~450
|
Operating Temperature Range(¡æ) |
-25~+85
|
Capacitance Tolerance(20¡æ,120Hz) |
¡À20%
|
Leakage current(¦ÌA) |
0.01CV or 5mA, whichever is smaller.(at 20¡æ, after 5
minutes)
Where C:Nominal Capacitance(¦ÌF) V:Rated Voltage(V)
|
Dissipation Factor |
200V~250V,DC:0.25
350V~450V,DC:0.20
|
Load Life(85¡æ) |
Time
|
2000 hours
|
Leakage current
|
Less than
the specified value.
|
Capacitance Change
|
Less than
¡À15% of the initial value.
|
Dissipation Factor
|
Not more than
175% of the specified value.
|
|
Shelf Life(85¡æ) |
Time
|
500 hours
|
Leakage current
|
Less than
the specified value.
|
Capacitance Change
|
Less than
¡À15% of the initial value.
|
Dissipation Factor
|
Not more than
175% of the specified value.
|
After test:UR to be applied